power entry modules without line filter kea-print www.schurter.com/pg0 5 connectors iec appliance inlet c14 with fuseholder 1- or 2-pole for pcb kea-print kea-print plug removal necessary for fuse replacement c14 70 c description - panel mount: screw-on version from front or rear side, snap-in version from front side - 2 functions: appliance inlet protection class i, fuseholder for fuse-links 5 x 20 mm 1- or 2-pole - for pcb mounting approvals - vde certificate number: 40012272 characteristics - all single elements are already wired - plug removal necessary for fuse-link replacement the fuse drawer fingergrip can be removed by hand for added safety "extra-safe" fuse drawers are available fuse drawer meets requirements of medical standard iec/en 60601-1 the fuseholder is accessible from the equipment front - qualified for use in equipment according iec/en 60950 other versions on request - with solder terminals - fuse drawer with other voltage values - for protection class ii references weblinks pd f , general product informatio n , approval s , roh s , china-roh s , mating connector s , e-stor e , schurter-stock-chec k , distributor- stock-chec k , accessorie s technical data ratings iec 10 a / 250 vac; 50 hz ratings ul/csa 10 a / 250 vac; 60 hz dielectric strength > 3 kvac between l-n > 4 kvac between l/n-pe (1 min/50 hz) allowable operation temp. -25 c to 70 c degree of protection from front side ip 40 acc. to iec 60529 protection class suitable for appliances with protection class 1 acc. to iec 61140 terminal for pcb 1,6 mm panel thickness s screw: max 8 mm mounting screw torque max 0.5 nm snap-in: 1.5/2/2.5 mm material: housing thermoplastic, black, ul 94v-0 appliance inlet c14 acc. to iec/en 60320-1, ul 498, csa c22.2 no. 42 (for cold conditions) pin-temperature 70 c, 10 a, protection class 1 fuseholder 1 or 2 pole, shocksafe category pc2 acc. to iec 60127-6, for fuse-links 5 x 20 mm rated power acceptance @ ta 23 c 5 x 20: 2 w (1 pole)/ 1.6 w (2-pole) per pole power acceptance @ ta > 23c admissible power acceptance at hig - her ambient temperature see derating curves
power entry modules without line filter kea-print www.schurter.com/pg0 5 connectors dimensions 44 mm screw-on mounting type kea-print r2.5 m3/?3.6 31.5 27.5 36 0.1 +0.2 0 +0.2 0 0 -0.2 27.2 r2.5 44 36 31.2 34 r4 r6 2.2 18.9 12.7 4 41.4 2 ? 6.3x90? ? 3.2 20.3 5.1 n 3 1-pole 2-pole 5 3 template grid 1/10" = 2.54 mm drill. ?: 3/5/n = ? 1.3 + 0,1/0 gnd = ? 1.6 + 0,1/0 snap-in mounting type kea-print r2.5 31.5 27.5 +0.2 0 +0.2 0 0 -0.2 27.2 r2.5 36 31.2 34 r4 2.2 18.9 12.7 41.4 2 20.3 5.1 n 3 1-pole 2-pole 5 3 s 0.1 template grid 1/10" = 2.54 mm drill. ?: 3/5/n = ? 1.3 + 0,1/0 gnd = ? 1.6 + 0,1/0
power entry modules without line filter kea-print www.schurter.com/pg0 5 connectors diagrams with internal connections 1-pole (kea-print) with internal connections 2-pole (kea-print) derating curves 1-pole admissible power acceptance in watt 0 2 0 4 0 6 0 8 0 100 i = < < i n i = 0.7 i n i = 1.0 i n 2.0 1.5 1.0 0.5 0.0 ambient air temperature ta c 2-pole admissible power acceptance in watt per pole 0 2 0 4 0 6 0 8 0 100 0.2 0.0 i = < < i n i = 0.7 i n i = 1.0 i n 1.6 0.6 0.4 0.8 1.2 1.0 1.4 ambient air temperature ta c variants fingergrip and extra-safe internal connections, fuse drawer must be ordered separately type panel mounting panel thickness s [mm] fuseholder voltage selectors internally wired order number kea-print screw - 1-pole without l 4301.3211 kea-print screw - 2-pole without l 4301.3201 kea-print snap-in 1.5 1-pole without l 4301.3212 kea-print snap-in 2 1-pole without l 4301.3213 kea-print snap-in 2.5 1-pole without l 4301.3214 kea-print snap-in 1.5 2-pole without l 4301.3202 kea-print snap-in 2 2-pole without l 4301.3203 kea-print snap-in 2.5 2-pole without l 4301.3204 packaging unit 50 pcs required accessor y description fusedrawer 2 fusedrawer with and without voltage selector insert fingergrip, 2-pole 4301.1401 extra-safe, 2-pole 4301.1403 fingergrip, 1-pole 4301.1405 extra-safe, 1-pole 4301.1407 ...
power entry modules without line filter kea-print www.schurter.com/pg0 5 connectors accessorie s cord retaining kit s cord retaining strain relief flat head, a 4700.0001 countersunk, b 4700.0002 mating outlets/connector s category / description appliance outletoverview complet e iec appliance outlet f, screw-on mounting, front side, solder terminal 478 7 iec appliance outlet f, snap-in mounting, front side, solder or quick-connect terminal 478 8 iec appliance outlet f or h, screw-on mounting, front side, solder, pcb or quick-connect terminal 509 1 iec appliance outlet f or h, screw-on mounting, front side, solder or quick-connect terminal 509 2 appliance outletfurther types tokea-prin t connectoroverview complet e iec connector c15, rewireable, straight 010 1 iec connector c15a, rewireable, straight 010 2 iec connector c15a, rewireable, straight 0102- g iec connector c15a, rewireable, angled 011 2 iec connector c13, rewireable, angled 401 2 connectorfurther types tokea-prin t ... power cordoverview complet e power cord with iec connector c13, angled 031 1 power cord with iec connector c13, angled 301 1 power cord with iec connector c13, angled 301 2 power cord with iec connector c13, angled 301 3 power cord with iec connector c13 302 0 power cordfurther types tokea-prin t ... the specifications, descriptions and illustrations indicated in this document are based on current information. all content is subject to modifications and amendments.
|